Senior OT / SCADA Integration & Commissioning Lead (Industrial Automation & Infrastructure Projects)
Location: London
ROLE PURPOSE
We are seeking a Senior OT / SCADA Integration & Commissioning Lead to support the delivery of complex industrial and infrastructure projects, with a focus on system integration, commissioning and technical coordination in field environments.
The role is designed for a senior technical professional evolved into coordination, capable of operating between:
- hands on SCADA / PLC work
- system-level integration
- coordination of EPC contractors, vendors and operations
This is not a pure Project Manager role, but a technical delivery and integration role.
ROLE CONTEXT
The position sits within projects characterised by:
- multi vendor SCADA environments
- complex OT system integration
- commissioning intensive phases
- interaction with EPCs, OEMs and plant operators
Key challenge: ensuring systems are not only installed, but fully integrated and operational in real conditions.
KEY RESPONSIBILITIES 3.1 Commissioning & Integration
- Lead and execute SCADA and control systems commissioning activities
- Validate integration between:
- PLC systems
- SCADA platforms
- third party/OEM systems
- Ensure correct behaviour of:
- signals
- commands vs feedback
- system states
3.2 Industrial Networks & Communications (Core Capability)
- Lead and support the configuration, validation and troubleshooting of industrial communication networks as a core part of system integration and commissioning.
Network Configuration & Infrastructure
- Work hands on with industrial network infrastructure, including:
- configuration of managed industrial switches
- IP addressing aligned with system architecture
- VLAN configuration and traffic segmentation
- basic routing concepts (subnets, gateways, inter network communication)
- Support and validate network topologies:
- star / ring / redundant architectures
- distributed I/O networks
- separation between control, SCADA and external systems
Industrial Protocols & Data Flow
- Ensure correct configuration and operation of: Profinet, Modbus TCP, OPC UA
- Validate end to end data flow across: field devices, PLCs, SCADA systems
- Identify and resolve:
- data inconsistencies or stale values
- intermittent communication
- addressing/configuration mismatch
- protocol level issues
Network Diagnostics & Troubleshooting
- Diagnose issues such as:
- connectivity failures
- latency / instability
- physical layer issues (cabling, ports, redundancy switching)
- switch misconfiguration
- Apply structured troubleshooting:
- trace signals (field PLC network SCADA)
- isolate root cause (logic vs network vs configuration)
- validate real vs displayed system state
Integration with System Behaviour
- Ensure network configuration supports:
- reliable command execution
- feedback consistency
- real time performance
- Detect scenarios where:
- systems appear functional but are degraded
- SCADA does not reflect real system state
Coordination with OT & Infrastructure Teams
- Interface with:
- network / IT / OT security
- vendors / integrators
- Align:
- network configuration
- system architecture
- commissioning requirements
Operational Reliability & Readiness
- Validate that networks are: stable, properly structured, aligned with system criticality
- Ensure readiness for: FAT / SAT, commissioning, handover
System Coherence & Cross Layer Ownership (PLC - Network - SCADA)
- Own and ensure end to end coherence of system behaviour across: field devices, PLC logic, industrial network, SCADA systems
Single Source of Truth
- Ensure full alignment between: PLC states, transmitted data, SCADA representation
- Resolve discrepancies between: commanded vs actual state, logic vs visualisation, real system vs operator perception
End to End Traceability
- Validate traceability of signals: field PLC network SCADA
- Diagnose issues by: tracing signal origin, analysing transformations, validating final behaviour
False State Detection
- Identify situations where:
- SCADA shows operation but system is not functioning
- feedback does not reflect real status
- communication creates false truths
- Ensure system avoids: misleading status, silent failures, undetected degradation
Cross-Domain Integration
- Ensure that: PLC logic, communications, SCADA operate as a single coherent system.
Resolution Ownership
- Take responsibility for resolving issues across: PLC, network, SCADA avoiding gaps between disciplines or vendors
Operational Trust
- Ensure system behaviour is: predictable, verifiable, aligned with reality
3.4 Technical Coordination
- Act as interface between: EPC contractors, SCADA vendors, engineering teams, operations
- Align implementation with operational needs
- Coordinate during: startup, shutdown, commissioning
3.5 System Validation & Troubleshooting
- Identify and resolve integration issues across: communications, SCADA PLC interaction, instrumentation
- Validate full system behaviour under real conditions
SCADA & OT Systems
- Support SCADA platforms: PcVue, PCS7, WinCC / AVEVA
- Ensure: proper alarms, monitoring, data coherence
3.7 Project Delivery Support
- Support FAT/SAT
- Contribute to delivery readiness
- Mitigate risks related to: Integration, sequencing, dependencies
REQUIRED PROFILE Experience
- Strong industrial automation / SCADA experience
- Strong experience in: commissioning, system integration, field environments
- Experience in: infrastructure / energy / industrial projects, EPC environments
- Real commissioning experience
- System level troubleshooting capability
- Ability to detect cross layer inconsistencies (PLC-Network-SCADA)
Technical Background
SCADA: PcVue, PCS7, WinCC, AVEVA
PLC: Siemens (TIA Portal preferred), Schneider, Codesys
Communications & Networks
- Profinet
- Modbus
- OPC UA
- industrial networks
- Practical experience in: switch configuration, network troubleshooting in field
Systems & Delivery
- commissioning
- integration
- coordination
Additional
- PV plants / energy
- industrial retrofit
- infrastructure systems
Please note that this job description does not represent a comprehensive list of activities and employees may be requested to undertake other reasonable duties.
Ferrovial is an equal opportunity employer. We treat all jobs applications equally, regardless of gender, color, race, ethnicity, religion, national origin, age, disability, pregnancy, sexual orientation, gender identity and expression, covered veteran status or protected genetic information (each, a "Protected Class"), or any other protected class in accordance with applicable laws.